Lithium-ion capacitor

Test data

> Inquiries regarding products

High heat-resistance

Demonstrates stable performance even in high temperature environments

Comparison of float charge resistance (85 ℃, 3.8V)

Change in internal resistance during float charging (85 ℃,3.8V)

Capacity change during float charging (85 ℃, 3.8V)

Change in internal resistance during float charging (65 ℃,3.6V)

Capacitance change during float charging (65 ℃, 3.6V)

low temperatures charactaristic

Large current can be supplied stably

Comparison of internal resistance increase in low temperatures

〈Test conditions〉
Conform to IEC62813-2015

Performance change during repeated charging and discharging at -40℃

〈Test conditions〉
500F 1 cell, maximum current 20 A (90 C), 85 sec/cycle

Internal resistance

Capacitance

Supports large current

Excellent durability against deterioration caused by self-heat generation during large current charge/discharge

Self-heat generation behavior during large current charge/discharge

〈Test conditions〉
500F 1 cell, maximum current 150 A (675 C), 45℃

Performance change with repeated large-current charging/discharging

〈Test conditions〉
2000F 1 cell, maximum current 480 A (540 C), 5 sec/cycle, 25℃

Internal resistance

Capacitance

Safeness

Cleared rigorous safety tests based on conforming to Chinese national standards (GB/T31485-2015)

Inquiries regarding products